The heating element on this page is mainly used on single group espresso machines produced by the Astoria CMA company. Meaning that these elements can be found in Astoria and Wega espresso machines. The Astoria part number for this item is 17002 and the Wega part number is WY17002 

This heating element has a immersed length of 175mm, in between these heating element coils there is also a spare tube for the heating element thermostat. This element produces 2000W at 230/240V. The heating element flange has a width of 95mm and a height of 57mm and the distance between the fixing holes is 75mm. The gasket used on this type of element has a outer diameter of 57mm a inner diameter of 43mm and a thickness of 3mm.

This heating element can be used on a variety of espresso machine models of Astoria like the Astoria Pratic, Astoria Divina, Astoria Gloria, Astoria Perla, Astoria Lisa, Astoria Dora and so on.

Astoria
13-123-L-1755604

Data sheet

Astoria CMA
Argenta
Brava
Calypso
Compact
Denise
Divina
Dora
Gloria
Pratic
Pratic new
Rapallo
Rapallo AL
Sibilla
Vania
Brand
Astoria
part number
Astoria 17002
Wega WY17002
Submerged length
175mm
Type part
Heating element
Voltage
230/240V
Watt
2000W

This does depend of which brand of espresso machine you have. Some espresso machine brands don’t use a heating element thermostat at all. Most thermostats are interchangeable with each other, but always make sure that you use a single phase or a 3 phase version, check out the thermostats we have on our website

Well first of all the heating element flange, seen those are in most cases not interchangeable with each other. seen a Cimbali heating element won’t fit a Nuova Simonelli heating element due to the flange model. A other important feature is the length of the heating element. When it is too long, it won’t fit. When the element is too short you will get uneven heat distribution in the boiler.

Well descaling a heating element is quite simple. A heating element can be placed inside a water tight tube. But the flange can not be submerged, the chance that water gets inside the heating element is possible. Which shorts out the element and makes it unuasable.

To descale a heating element you can use Puly caff Calcinet descaler, this need to be dissolved into hot water. First remove the loose lime scale. If it doesn’t remove all the limescale, repeat the procedure.

A heating element only comes with a gasket when this is specified. If this is not specified a heating element gasket isn’t supplied with the element.