Nuova Simonelli heating element 2 gr 3000W 230/400V
search
  • Nuova Simonelli heating element 2 gr 3000W 230/380V
  • Nuova Simonelli heating element 2 gr 3000W 230/400V

Nuova Simonelli heating element 2 gr 3000W 230/400V


€102.90

€102.90 tax excl.

qty
Shipment after 5 - 10 working days*

  GDPR Compliance

Protecting your personal data

  Shipping policy

Everything about shipping your order

  Return policy

all the inns and outs about our return policy

This 2 group heating element is suitable for various espresso machine models and brands such as Victoria Arduino and Nuova Simonelli. The part references for the Nuova Simonelli 14100011  and for Victoria Arduino 14100011.

This heating element produces 3000W at 230/400V and has 6 connecting poles on the flange. The immersed length of the element is 345mm. The flange has the dimensions of 92/77mm. the hole distances are 55/30mm. This element is made in Italy.

The type of heating element gasket you need is one which has a outer diameter of 67mm a inner diameter of 55mm and a thickness of 3mm.

You can use this heating element on models such as the Victoria Arduino Athena, Victoria Arduino Athena Leva, Nuova Simonelli Aurelia, Nuova Simonelli Aurelia II, Nuova Simonelli Appia and the Nuova Simonelli Program Vip.

13-054-L-1755142

Data sheet

Brand
Nuova Simonelli
Victoria Arduino
Country of manufacturing
Made in Italy
Nuova Simonelli
Appia
Aurelia
Aurelia II
Program Vip
part number
Nuova Simonelli 14100011
Victoria Arduino 14100011
Submerged length
345mm
Type part
Heating element
Victoria Arduino
Athena Leva
Voltage
230/400V
Watt
3000W

This does depend of which brand of espresso machine you have. Some espresso machine brands don’t use a heating element thermostat at all. Most thermostats are interchangeable with each other, but always make sure that you use a single phase or a 3 phase version, check out the thermostats we have on our website

Well first of all the heating element flange, seen those are in most cases not interchangeable with each other. seen a Cimbali heating element won’t fit a Nuova Simonelli heating element due to the flange model. A other important feature is the length of the heating element. When it is too long, it won’t fit. When the element is too short you will get uneven heat distribution in the boiler.

Well descaling a heating element is quite simple. A heating element can be placed inside a water tight tube. But the flange can not be submerged, the chance that water gets inside the heating element is possible. Which shorts out the element and makes it unuasable.

To descale a heating element you can use Puly caff Calcinet descaler, this need to be dissolved into hot water. First remove the loose lime scale. If it doesn’t remove all the limescale, repeat the procedure.

A heating element only comes with a gasket when this is specified. If this is not specified a heating element gasket isn’t supplied with the element.